Epoxy Board / G10
G10 Epoxy

Epoxy Board / G10

G10 Industrial Grade

Phenolic and G10 epoxy-glass board, 0.3–50 mm thick, with double-side grinding, CNC routing, drilling and tapping. High strength, good insulation and moisture resistance for transformers, motors, fixtures and insulation structures; FR4 V-0 grade available.

  • ✓Industrial G10 epoxy-glass laminate, non-flame-retardant (UL94 HB), Tg 115°C — built for structural parts
  • ✓High mechanical strength: flexural ≥380 MPa, compressive ≥350 MPa
  • ✓Insulation and moisture resistance: breakdown ≥45 kV/mm, water absorption ≤0.20%
  • ✓0.3–50 mm thick; standard sheets 914×1220 mm and 1220×2440 mm
  • ✓Double-side grinding, CNC routing, drilling/tapping and precision cutting

Specifications

Technical Specifications
ItemSpecification
MaterialG10/FR4 epoxy-glass composite
GradeG10 industrial grade
Thickness range0.3mm - 50mm
Temperature resistance≥130 °C (standard G10)
Breakdown voltage≥20kV/mm
Water absorption≤0.1%
CustomCut to any size
Standard Sizes
Thickness (mm)Standard sheet size (mm)Common grade
1.0914 x 1220G10 / FR4
1.6914 x 1220 / 1220 x 2440G10 / FR4
2.0914 x 1220 / 1220 x 2440G10 / FR4
3.0914 x 1220 / 1220 x 2440G10 / FR4
5.01220 x 2440G10 / FR4
6.01220 x 2440G10 / FR4
8.01220 x 2440G10 / FR4
10.01220 x 2440G10 / FR4
12.01220 x 2440G10 / FR4
15.01220 x 2440G10 / FR4
20.01220 x 2440G10 / FR4
25.01220 x 2440G10 / FR4
Material Properties
PropertyG10 (non-FR)FR4 (flame retardant)
Flame ratingNone (UL 94 HB)V-0 (UL 94)
Glass transition Tg115 C130 C
Flexural strength≥380 MPa≥415 MPa
Compressive strength≥350 MPa≥400 MPa
Water absorption≤0.20%≤0.50%
Insulation resistance≥10^8 MOhm≥10^6 MOhm.cm
Dielectric breakdown strength≥45 kV/mm≥40 kV/mm
Service temperature range-40 to +105 °C-40 to +130 °C
Surface Treatment Options
TreatmentRemarkApplication
As suppliedStandard surface, slightly tackyGeneral insulation
Light sandingSanded to uniform thicknessCNC blanks
Precision grindingGround both sides to tight tolerancePrecision parts
Drilling / counterboringPre-machined holes and edgesAssembly-ready parts

Applications

Transformer Insulation
Motor Insulation
High Voltage Switchgear
Electronic Circuit Boards
Precision Instruments
Military Equipment

G10 / Phenolic Fabrication Capabilities

✂️

Precision Cutting

Sawing, die cutting and slitting to drawing size

Per drawing
🖥️

CNC Routing

Profiles, slots, steps, counterbores and 3D features

Per drawing
🕳️

Drilling & Tapping

Hole arrays, through holes and threads, with fixtures for repeatability

Per drawing
📏

V-CUT, Chamfer & Deburring

V-scoring, edge chamfering and burr removal

Per drawing
🧱

Double-Side Grinding

Ground to specified thickness for flatness on thick stock

Per drawing
🖨️

Screen Printing & Marking

Part number, polarity, batch and traceability marks

Per drawing

From Drawing to Delivery

STEP 01 Send Drawing / Spec PDF / DXF / DWG / STEP or a physical sample
STEP 02 Material & Thickness Grade chosen by temperature, flame rating, strength and cost
STEP 03 Prototype Approval MOQ 1 pc, 24h sampling
STEP 04 Cutting & CNC Cutting, routing, drilling, chamfering, printing
STEP 05 QC & Shipping Key dimensions checked + interleaved packing

Selection Guide

Selection order: V-0 required → FR4; higher strength and lower absorption without flame rating → G10; thick insulation structures (over 6 mm) → 3240; low-voltage, cost-sensitive → phenolic board. Thickness follows mechanical load and insulation distance — mark key dimensions and tolerances before machining.

Custom cutting to any size · Machining from drawing or sample · 24h sampling

Phenolic Board, Electrical Grade: X, XX, XXX and 3025 / 3026

"Electrical grade phenolic board" is a family, not a single material. It is a paper- or fabric-base laminate bonded with phenolic resin — the same material many buyers still call bakelite. Two boards can both be sold as "electrical grade" and still differ by a factor of two in insulation performance, so the grade designation is the only thing that makes a quote comparable.

GradeBaseElectrical performanceTypical use
XPaper-base phenolicMediumGeneral insulation, mounting plates, low-voltage spacers
XXPaper-base phenolicHighSwitch bases, terminal boards, relay and contactor parts
XXXPaper-base phenolicHighest of the X seriesHigh-voltage barriers, transformer insulation, busbar supports
3025Paper-base phenolicHigh, general purposeInsulation washers, spacers, low-cost structural parts
3026Paper-base phenolicHigh, with higher mechanical strengthThicker sections under load, supports, wear parts

X / XX / XXX follow the NEMA laminate designations; 3025 and 3026 are the grade numbers commonly quoted in China for paper-base phenolic sheet. Confirm the exact standard with your drawings — the same grade number can be issued against different tolerances.

Electrical grade phenolic vs G10 / FR4 — the honest comparison

How to specify the grade correctly

  1. State the grade and the standard — "XXX per NEMA", or "3025" — not just "electrical grade".
  2. Give the working voltage and the pollution degree. Above a few hundred volts a thicker grade matters more than a higher one.
  3. State the maximum ambient temperature. If it is above 130 °C, move to epoxy-glass.
  4. Say whether flammability applies. If it does, phenolic is out and FR4 is the answer.
  5. Send the drawing with thickness tolerance, flatness and hole positions — phenolic moves slightly after machining on thin sections.

Ask which grade fits your part

Comparing phenolic against glass-epoxy? See FR4 vs G10: what actually differs for the grade-by-grade table, or the four-material comparison.

Quality & Inspection

Incoming Inspection

Grade, thickness, appearance and batch checked before stocking

First Article

First part checked against drawing before the batch runs

In-Process & Outgoing Checks

Key dimensions sampled, appearance graded, inspection records on request

Protective Packing

Interleaving, individual bags or dividers against edge damage

Flame rating, temperature, dielectric strength and water absorption are tied to specific grades and test methods; mill certificates or third-party reports are provided on request — no blanket guarantees.

G10 / Phenolic FAQ

What is the difference between G10 and FR4?

Both are epoxy-glass laminates; they differ in flame rating and temperature. G10: UL94 HB, Tg 115°C, -40 to 105°C, flexural ≥380 MPa, water absorption ≤0.20%, breakdown ≥45 kV/mm. FR4: V-0, Tg 130°C, up to 130°C, flexural ≥415 MPa, absorption ≤0.50%, breakdown ≥40 kV/mm. G10 is cheaper and machines nicely for structural parts; FR4 suits electrical parts needing flame retardance.

  • Applies:Fixtures, structural supports and insulation blocks.
  • Not for:Do not use G10 where V-0 or >105°C continuous is required.
  • Please provide:Temperature, flame requirement, thickness and process.
Is phenolic board the same as G10 epoxy board?

No. Phenolic board is a paper or fabric laminate with phenolic resin — cheaper and easy to machine, but lower temperature and insulation margin than epoxy-glass. G10 is epoxy resin with woven glass cloth, giving better strength, insulation and moisture resistance. We supply both lines; selection depends on temperature, strength, insulation class and cost.

  • Applies:Phenolic for low-voltage insulation, backing plates and general structures; G10 where strength and insulation matter more.
  • Not for:Avoid standard phenolic in high-voltage, hot or humid service.
  • Please provide:Voltage, temperature, humidity and mechanical load.
What thickness and sheet size are available?

0.3–50 mm, commonly 1.0 / 1.6 / 2.0 / 3.0 / 5.0 / 6.0 / 8.0 / 10.0 mm; standard sheets 914×1220 mm and 1220×2440 mm, thick stock mostly 1220×2440 mm. Cut to any size from your drawing.

  • Applies:Insulation backers, machining blanks and fixture bases.
  • Not for:Above 50 mm requires lamination or another material.
  • Please provide:Thickness, size, quantity and surface (as-is, sanded or ground).
What does "electrical grade" mean on a phenolic board?

It refers to the paper-base phenolic laminate grades intended for insulation duty rather than mechanical duty — NEMA X, XX and XXX, or the Chinese grade numbers 3025 and 3026. The higher the grade, the better the insulation resistance and the dielectric strength after humidity ageing, and the stricter the tolerance on voids and foreign matter. "Electrical grade" on its own is not a specification: XX and XXX can differ two-fold in performance at the same thickness, so quotes should always name the grade.

  • Applies:Switch bases, terminal boards, barriers and transformer parts.
  • Not for:Flame-retardant or high-temperature duty above roughly 130 °C — use FR4 or G10.
  • Please provide:Grade and standard, working voltage, thickness, drawing.

Related Products

FR4 fiberglass sheet
Fiber Glass

FR4 Fiberglass Insulation Sheet

Professional FR4 fiberglass insulation board manufacturer. UL94 V-0 flame retardant, thickness 0

  • FR4 glass-fiber
  • UL94 V-0
View details →
3240 epoxy board
3240 Epoxy

3240 Epoxy Board

3240 epoxy fiberglass board manufacturer in China. F-class insulation, thickness 0.5-50mm. Ideal

  • 3240 epoxy-glass
  • Class F (155 °C)
View details →
Polycarbonate sheet
Polycarbonate (PC)

Custom PC Parts

Custom polycarbonate (PC) parts built to your drawing or sample, for impact protection, guarding

  • Polycarbonate (P
  • 860 J/m (ASTM D2
View details →

Request a Quote

Tell us your specs — reply within 24 hours.

Get a Quote

Inquiry: Epoxy Board / G10

Leave your requirements and contact info; we reply within 24 hours.

Email us 137 1259 3248134 3388 5009
📞 Call 💬 Email Inquiry