FR4 Fiberglass Insulation Sheet
Professional FR4 fiberglass insulation board manufacturer. UL94 V-0 flame retardant, thickness 0
- FR4 glass-fiber
- UL94 V-0
SQ/UC Flat Wire Type
Professional SQ/UC flat wire common mode inductor supplier. Low DCR, high frequency filtering. Ideal for 65W PD adapters, EV chargers, LED drivers. IATF16949 certified, 24h prototyping, global export to 30+ countries.
| Item | Specification |
|---|---|
| Type | SQ/UC flat wire common mode choke |
| Inductance range | 1mH – 50mH |
| Rated current | 1A – 30A |
| DC resistance | Low DCR design |
| Operating temperature | -40 to +125 °C |
| Flame rating | UL94 V-0 / HB |
| Wire size | 0.5×3 mm / 0.8×4 mm / custom |
| Typical application | 65 W PD adapters, onboard chargers (OBC) |
| Series | Wire type | DCR range | Current range | Typical application |
|---|---|---|---|---|
| SQ-T | SQ (square core), trapezoidal wire | 0.5-15 mOhm | 3A-30A | PD adapters, EV chargers |
| SQ-R | SQ rectangular wire | 0.3-8 mOhm | 5A-50A | Industrial power supplies |
| UC-R | UC (D-shaped core), round wire | 1.0-20 mOhm | 2A-20A | Telecom, server PSUs |
| UC-T | UC trapezoidal wire | 0.8-12 mOhm | 3A-25A | 5G base stations |
| Parameter | Range | Test condition |
|---|---|---|
| Common mode inductance | 1mH - 50mH | 100kHz / 0.1V |
| Differential mode inductance | 5uH - 500uH | 100kHz / 0.1V |
| DCR (typical) | 0.3mOhm - 20mOhm | 25 C |
| Saturation current (Isat) | 3A - 50A | Delta L/L = -20% |
| Rated current (Irated) | 2A - 40A | ΔT = 40 °C rise |
| Self-resonant frequency (SRF) | 500kHz - 10MHz | At peak impedance |
| Common mode impedance | 1kOhm - 50kOhm | typical at 10 MHz |
| Hi-pot (winding to core) | 500V - 2000V AC | 1 min / 5 mA |
| Operating temperature | -40 to +125 °C | Full load |
| Application | Recommended series | Key requirement |
|---|---|---|
| 65–100 W PD chargers | SQ-T10 / UC-T8 | Low DCR, compact |
| EV home chargers (7–22 kW) | SQ-R15 / SQ-T20 | High current, low heating |
| 5G base station PSUs | UC-T / SQ-T | HF, low EMI |
| Server PSUs (CRPS) | UC-R / SQ-R | High efficiency, good cooling |
| PV inverters | SQ-R / UC-R | High reliability, heat resistant |
| Industrial SMPS | SQ-R / UC-R | General purpose |
| Property | Flat wire (SQ/UC) | Round wire |
|---|---|---|
| Fill factor | 95%+ (round wire ~78%) | ~78% |
| DCR reduction | 20–40% lower | Baseline |
| Heat dissipation | Significantly better | Medium |
| Leakage inductance | Lower | Higher |
| HF EMI suppression | Excellent | Good |
| Cost | Medium (higher wire cost) | Lower |
| Winding difficulty | Higher (dedicated equipment) | Standard process |
Automatic flat-wire winding for SQ and UC types, high fill factor
Per datasheetMnZn / NiZn ferrite and nanocrystalline, matched to frequency and current
Per datasheetVacuum impregnation for insulation, mechanical fixing and lower buzz
Per datasheetRadial/axial leads, taped or tray packing for automated lines
Per drawingL, DCR, hi-pot and inter-winding short tested piece by piece
100%Custom inductance, wire size, leads, package and taping
Per datasheetSelection path: define switching frequency and rated current → pick the series (3–30 A: SQ-T; 5–50 A: SQ-R; 2–20 A: UC-R; 3–25 A: UC-T) → check DCR and temperature rise → verify EMI margin on samples. Choose UC for tight spaces and SQ-R for high current with low heating.
Custom cutting to any size · Machining from drawing or sample · 24h sampling
7 kW sits between single-phase and three-phase power design — EV on-board chargers, telecom and edge rectifiers, industrial drives and high-power lighting supplies all land in this band. At this level the common mode choke stops being a commodity part: it is usually the largest magnetic component on the EMI filter, and it is one of the first parts to fail a conducted emission scan.
| Platform | Input | Rated current | Inductance window | DCR target |
|---|---|---|---|---|
| 7 kW EV OBC (single-phase) | 230 V AC | 30–32 A | 1–4 mH | ≤ 6 mΩ |
| 7 kW EV OBC (three-phase) | 400 V AC | 11–16 A | 2–6 mH | ≤ 12 mΩ |
| 7 kW telecom / edge rectifier | 230 V AC | 32–35 A | 1–3 mH | ≤ 5 mΩ |
| 7 kW industrial drive front end | 400 V AC | 12–18 A | 2–8 mH | ≤ 15 mΩ |
Windows above are starting points for a first sample, not a specification. Final inductance follows your conducted emission margin at the switching frequency — send the scan and we will size it against the actual curve.
Buyers often compare on inductance and current alone, then find a 40% gap between two quotes for parts that look identical on paper. The difference is almost always in these five places:
To price a 7 kW EMI filter choke accurately, send these six items and we will quote the same construction to every supplier you are comparing:
Samples from 24 h, with L / DCR / hi-pot data on the report. Volume pricing is quoted against the annual quantity, not a one-off batch.
Running a 30–120 kW rack power shelf? The same choke family is specified for AI server PSUs — see AI server power supply inductor selection for the rack-level current, copper-loss and thermal numbers.
Core dimensions and AL value, wire spec and enamel continuity sampled
L, DCR, hi-pot and inter-winding short on every piece
Lead position, adhesive, marking and outline checked to datasheet
Taped or trayed, batch traceable to winding and test records
Inductance, DCR and hi-pot follow the approved datasheet and measured reports; batch consistency is checked by AQL sampling — state special requirements in your inquiry.
SQ uses a square core with flat (trapezoidal/rectangular) wire; UC uses a D-shaped core with round or flat wire. SQ-T covers 3–30 A at 0.5–15 mΩ; SQ-R covers 5–50 A at 0.3–8 mΩ for industrial supplies; UC-R covers 2–20 A at 1.0–20 mΩ, common in telecom and server PSUs.
Common mode inductance typically 1–50 mH (100 kHz / 0.1 V), rated current defined at 40°C rise, saturation at 20% inductance drop. Leave EMI margin and check SRF (500 kHz–10 MHz). Send your operating conditions and we will propose a selection, then verify by sample.
Yes — inductance, wire size and profile, lead style, package and taping are all customizable. Sampling starts from 24 h, and measured data is provided for approval before volume production.
There is no single price, because at 30 A the part is defined by construction rather than by inductance alone. The quote is driven by core material and size, copper weight and wire profile, impregnation and lead forming, and how much testing you require. A 7 kW choke built for a 30 A single-phase input costs more than the 16 A part in a 3 kW design — mainly copper, not core. Send the input voltage, switching frequency, target inductance, size limit and annual volume, and we quote a fixed construction so two suppliers can be compared like for like.
Professional FR4 fiberglass insulation board manufacturer. UL94 V-0 flame retardant, thickness 0
Custom polycarbonate (PC) parts built to your drawing or sample, for impact protection, guarding
Custom acrylic (PMMA) parts built to your drawing or sample, for high-clarity display, signage a
Leave your requirements and contact info; we reply within 24 hours.